Template:Ambient: Difference between revisions
No edit summary |
No edit summary |
||
Line 10: | Line 10: | ||
|} | |} | ||
==Table of ambient ionization techniques== | |||
Tabulated [[ambient ionization]] techniques. Click the header box to sort. | |||
{|class="wikitable sortable" cellpadding="15" width="85%" | |||
! align="left"| Acronym | |||
! align="left" |Technique | |||
! align="left" |Material Removal | |||
! align="left" |Ionization | |||
! align="left" |Classification | |||
! align="left" |Reference | |||
|- | |||
|[[ASAP]] | |||
|[[Atmospheric pressure solids analysis probe]] | |||
|Heat | |||
|[[Chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1021/ac051470k | |||
|- | |||
|[[APTDI]] | |||
|[[Atmospheric pressure thermal desorption/ionization]] | |||
|Heat | |||
| | |||
|[[#Plasma]] | |||
| | |||
|- | |||
|[[BADCI]] | |||
|[[Beta electron-assisted direct chemical ionization]] | |||
|Heat | |||
|[[Metastable chemical ionization]] | |||
|[[#Two step]] | |||
|{{doi}}10.1039/B909072J | |||
|- | |||
|[[DAPCI]] | |||
|[[Desorption atmospheric pressure chemical ionization]] | |||
|Heat | |||
|[[Chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1039/B418697D | |||
|- | |||
|[[DAPPI]] | |||
|[[Desorption atmospheric pressure photoionization]] | |||
|Heat | |||
|[[Photoionization]] | |||
|[[#Extraction]] | |||
|{{doi}}10.1021/ac071152g | |||
|- | |||
|[[DART]] | |||
|[[Direct analysis in real time]] | |||
|Heat | |||
|[[Metastable chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1021/ac050162j | |||
|- | |||
|[[DBDI]] | |||
|[[Dielectric barrier discharge ionization]] | |||
|Heat | |||
|[[Metastable chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1016/j.jasms.2007.07.027 | |||
|- | |||
|[[DCBI]] | |||
|[[Desorption corona beam ionization]] | |||
|Heat | |||
|[[Metastable chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1039/B922616H | |||
|- | |||
|[[DCI]] | |||
|[[Desorption chemical ionization]] | |||
|Heat | |||
|[[Chemical ionization]] | |||
|[[#Plasma]] | |||
| | |||
|- | |||
|[[DEMI]] | |||
|[[Desorption electrospray/metastable-induced ionization]] | |||
|Solvent extraction | |||
|[[Electrospray]]/[[Metastable chemical ionization]] | |||
|[[#Multimode]] | |||
|{{doi}}10.1021/ac9014098 | |||
|- | |||
|[[DESI]] | |||
|[[Desorption Electrospray Ionization]] | |||
|Liquid extraction | |||
|[[Electrospray]] | |||
|[[#Extraction]] | |||
| | |||
|- | |||
|[[DICE]] | |||
|[[Desorption ionization by charge exchange]] | |||
|Liquid extraction | |||
| | |||
|[[#Extraction]] | |||
| | |||
|- | |||
|[[EASI]] | |||
|[[Easy ambient sonic-spray ionization]] | |||
|Liquid extraction | |||
|Droplet evaporation | |||
|[[#Extraction]] | |||
|{{doi}}10.1021/ac701960q | |||
|- | |||
|[[EESI]] | |||
|[[Extractive electrospray ionization]] | |||
|Aerosol extraction | |||
|[[Electrospray]] | |||
|[[#Two step]] | |||
|{{doi}}10.1039/b602614a | |||
|- | |||
|[[ELDI]] | |||
|[[Electrospray laser desorption ionization]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Laser]] | |||
|{{doi}}10.1002/rcm.3011 | |||
|- | |||
|[[HAPGDI]] | |||
|[[Helium atmospheric pressure glow discharge ionization]] | |||
| | |||
| | |||
|[[#Plasma]] | |||
| | |||
|- | |||
|[[IR-LAMICI]] | |||
|[[Infrared laser ablation metastable-induced chemical ionization]] | |||
|Laser | |||
|[[Metastable chemical ionization]] | |||
|[[#Laser]] | |||
|{{doi}}10.1021/ac902905v | |||
|- | |||
|[[LADESI]] | |||
|[[Laser assisted desorption electrospray ionization]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Laser]] | |||
|{{doi}}10.1039/b715146b | |||
|- | |||
|[[LAESI]] | |||
|[[Laser ablation electrospray ionization]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Laser]] | |||
|{{doi}}10.1021/ac071181r | |||
|- | |||
|[[LA-FAPA]] | |||
|[[Laser ablation flowing atmospheric pressure afterglow]] | |||
|Laser | |||
|Plasma | |||
|[[#Laser]] | |||
|{{doi}}10.1021/ac801594u | |||
|- | |||
|[[LA-ICP]] | |||
|[[Laser ablation inductively coupled plasma]] | |||
|Laser | |||
|Plasma | |||
|[[#Laser]] | |||
| | |||
|- | |||
|[[LDAPCI]] | |||
|[[Laser desorption atmospheric pressure chemical ionization]] | |||
|Laser | |||
|[[APCI]] | |||
|[[#Laser]] | |||
|{{doi}}10.1021/ac020402k | |||
|- | |||
|[[LDESI]] | |||
|[[Laser desorption electrospray ionization]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Laser]] | |||
|{{doi}} | |||
|- | |||
|[[LDI]] | |||
|[[Laser desorption ionization]] | |||
|Laser | |||
| | |||
|[[#Other]] | |||
| | |||
|- | |||
|[[LEMS]] | |||
|[[Laser electrospray mass spectrometry]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Laser]] | |||
|{{doi}}10.1002/rcm.4226 | |||
|- | |||
|[[LESA]] | |||
|[[Liquid extraction surface analysis]] | |||
|[[Liquid microjunction]] | |||
|[[Electrospray]] | |||
|[[#Extraction]] | |||
| | |||
|- | |||
|[[LIAD-ESI]] | |||
|[[Laser-induced acoustic desorption-electrospray ionization]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Acoustic]] | |||
|{{doi}}10.1021/ac800896y | |||
|- | |||
|[[LMJ-SSP]] | |||
|[[Liquid microjunction-surface sampling probe]] | |||
|[[Liquid microjunction]] | |||
|[[Electrospray]] | |||
|[[#Extraction]] | |||
|{{doi}}10.1021/ac901098d | |||
|- | |||
|[[LSI]] | |||
|[[Laser spray ionization]] | |||
|Laser | |||
|Droplet evaporation | |||
|[[#Other]] | |||
|{{doi}}10.1074/mcp.M900527-MCP200 | |||
|- | |||
|[[LTP]] | |||
|[[Low temperature plasma]] | |||
|Heat | |||
|[[Metastable chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1021/ac801641a | |||
|- | |||
|[[MAII]] | |||
|[[Matrix-assisted inlet ionization]] | |||
|Aerosol | |||
|Droplet evaporation | |||
|[[#Other]] | |||
|{{doi}}10.1021/ac102339y | |||
|- | |||
|[[MALDESI]] | |||
|[[Matrix-assisted laser desorption electrospray ionization]] | |||
|Laser | |||
|[[Electrospray]] | |||
|[[#Laser]] | |||
|http://dx.doi.org/10.1016/j.jasms.2006.08.003 | |||
|- | |||
|[[nano-DESI]] | |||
|[[Nanospray desorption electrospray ionization]] | |||
|[[Liquid microjunction]] | |||
|[[Electrospray]] | |||
|[[#Extraction]] | |||
|{{doi}}10.1039/C0AN00312C | |||
|- | |||
|[[ND-EESI]] | |||
|[[Neutral desorption extractive electrospray ionization]] | |||
|Gas | |||
|[[Electrospray]] | |||
|[[#Two step]] | |||
|{{doi}}10.1002/jms.1282 | |||
|- | |||
|[[PADI]] | |||
|[[Plasma-assisted desorption ionization]] | |||
|Heat | |||
|[[Metastable chemical ionization]] | |||
|[[#Plasma]] | |||
|{{doi}}10.1021/ac070109q | |||
|- | |||
|[[PESI]] | |||
|[[Probe electrospray ionization]] | |||
|Solid extraction | |||
|[[Electrospray]] | |||
|[[#Two step]] | |||
|{{doi}}10.1002/rcm.3201 | |||
|- | |||
|[[PS]] | |||
|[[Paper spray]] | |||
|Solid extraction | |||
|[[Electrospray]] | |||
| | |||
|{{doi}}10.1021/ac902854g | |||
|- | |||
|[[RADIO]] | |||
|[[Radiofrequency acoustic desorption and ionization]] | |||
|Acoustic | |||
|[[Electrospray]] | |||
|[[#Acoustic]] | |||
|{{doi}}10.1016/j.jasms.2008.11.024 | |||
|- | |||
|[[RASTIR]] | |||
|[[Remote analyte sampling transport and ionization relay]] | |||
|Gas | |||
|[[Electrospray]] | |||
| | |||
|{{doi}}10.1021/ac800289f | |||
|- | |||
|[[REIMS]] | |||
|[[Rapid evaporative ionization mass spectrometry]] | |||
|Heat | |||
|Charge separation | |||
|[[#Other]] | |||
|{{doi}}10.1002/anie.200902546 | |||
|- | |||
|[[SACI]] | |||
|[[Surface activated chemical ionization]] | |||
|Heat | |||
|[[Chemical ionization]] | |||
| | |||
|{{doi}}10.2174/138620709787315427 | |||
|- | |||
|[[SAII]] | |||
|[[Solvent-assisted inlet ionization]] | |||
|Heat | |||
|Droplet evaporation | |||
|[[#Other]] | |||
|{{doi}}10.1021/ac201982r | |||
|- | |||
|[[SPAMS]] | |||
|[[Single-particle aerosol mass spectrometry]] | |||
|Aerosol | |||
|[[Laser desorption ionization]] | |||
|[[#Other]] | |||
|{{doi}}10.1021/ac901208h | |||
|- | |||
|[[TM-DESI]] | |||
|[[Transmission mode desorption electrospray ionization]] | |||
|Liquid extraction | |||
|[[Electrospray]] | |||
|[[#Extraction]] | |||
| | |||
|} | |||
==Classification== | |||
From {{doi}}10.1021/cr300309q (Monge, M. E.; Harris, G. A.; Dwivedi, P.; Fernandez, F. M. Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. ''Chem. Rev.'' '''2013''', ''113'', 22692308) | |||
===Extraction=== | |||
"One-step techniques where desorption occurs by solid?liquid extraction processes dynamically followed by ESI, APPI, sonic spray, or CI ion production mechanisms" | |||
===Plasma=== | |||
"One-step plasma-based techniques involving thermal or chemical sputtering desorption of neutrals working in parallel with chemical ionization mechanisms" | |||
===Two step=== | |||
"Two-step techniques involving thermal desorption or mechanical ablation followed by secondary ionization" | |||
===Laser=== | |||
"Two-step techniques involving laser desorption/ablation followed by secondary ionization" | |||
===Acoustic=== | |||
"Two-step acoustic desorption methods" | |||
===Multimode=== | |||
"Multimode techniques involving two of the principles in previous categories" | |||
===Other=== | |||
"One-of-a-kind techniques that do not fit into previous categories" | |||
==See also== | ==See also== |
Revision as of 11:51, 11 August 2014
This ambient ionization page does not have content at this time, but you may be able to find information on this topic in the following places:
Or see Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013) |
Table of ambient ionization techniques
Tabulated ambient ionization techniques. Click the header box to sort.
Classification
From http://dx.doi.org/10.1021/cr300309q (Monge, M. E.; Harris, G. A.; Dwivedi, P.; Fernandez, F. M. Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. Chem. Rev. 2013, 113, 22692308)
Extraction
"One-step techniques where desorption occurs by solid?liquid extraction processes dynamically followed by ESI, APPI, sonic spray, or CI ion production mechanisms"
Plasma
"One-step plasma-based techniques involving thermal or chemical sputtering desorption of neutrals working in parallel with chemical ionization mechanisms"
Two step
"Two-step techniques involving thermal desorption or mechanical ablation followed by secondary ionization"
Laser
"Two-step techniques involving laser desorption/ablation followed by secondary ionization"
Acoustic
"Two-step acoustic desorption methods"
Multimode
"Multimode techniques involving two of the principles in previous categories"
Other
"One-of-a-kind techniques that do not fit into previous categories"
See also
References
- Badu-Tawiah, A. K., Eberlin, L. S., Ouyang, Z., & Cooks, R. G. (2013). Chemical Aspects of the Extractive Methods of Ambient Ionization Mass Spectrometry. Annual Review of Physical Chemistry, 64(1), 481505. http://dx.doi.org/10.1146/annurev-physchem-040412-110026
- Monge, M. E., Harris, G. A., Dwivedi, P., & Fernandez, F. M. (2013). Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. Chemical Reviews, 113(4), 22692308. http://dx.doi.org/dx.doi.org/10.1021/cr300309q
- Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2012). Mass spectrometry imaging under ambient conditions. Mass Spectrometry Reviews; http://dx.doi.org/10.1002/mas.21360
- Harris, G. A., Galhena, A. S., & Fernandez, F. M. (2011). Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends. Analytical Chemistry, 83, 45084538; http://dx.doi.org/10.1021/ac200918u
- Weston, D. J. (2010). Ambient ionization mass spectrometry: current understanding of mechanistic theory; analytical performance and application areas. The Analyst, 135(4), 661668; http://dx.doi.org/10.1039/b925579f