Nier-Johnson geometry: Difference between revisions
|  rm section heads , Replaced: == Orange Book entry == ‚Üí <!-- Orange Book -->, using AWB | No edit summary | ||
| Line 2: | Line 2: | ||
| Arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/2 radians in a radial [[electric field]] analyzer is followed by a [[magnetic deflection]] of π/3 radians. | Arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/2 radians in a radial [[electric field]] analyzer is followed by a [[magnetic deflection]] of π/3 radians. | ||
|   }} |   }} | ||
| {{Rev5| | |||
| Arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic energy analyzer is combined with a magnetic deflection of π/3 radians. | |||
| Related term:  Mattauch-Herzog geometry. | |||
| | | |||
| #[[Orange Book]] | |||
| #[[Gold Book]] | |||
| }} | |||
| <!-- Orange Book --> | <!-- Orange Book --> | ||
| {{orange| | {{orange| | ||
| An arrangement for a [[ | An arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a [[magnetic deflection]] of π/3 radians. The [[electrostatic analyser]] uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. | ||
| }} | }} | ||
| {{gold| | |||
| http://goldbook.iupac.org/N04141.html | |||
| An arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a magnetic deflection of π/3 radians. The electrostatic analyser uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. | |||
| Source: | |||
| PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | |||
| [[Orange Book]], p. 201 | |||
| }} | |||
| == See also == | == See also == | ||
| *[[Double-focusing mass spectrometer]] | *[[Double-focusing mass spectrometer]] | ||
Revision as of 22:09, 6 June 2010
Obsolete Template
This template is no longer used.
Orange Book
| ORANGE BOOK DEFINITION IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) | 
| Nier-Johnson geometry | 
|---|
| An arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a magnetic deflection of π/3 radians. The electrostatic analyser uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. | 
| IUPAC 1997 Orange Book Chapter 12 | 
| Index of Orange Book Terms | 
Gold Book
| GOLD BOOK DEFINITION IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). | 
| Nier-Johnson geometry | 
|---|
| http://goldbook.iupac.org/N04141.html An arrangement for a double-focusing mass spectrometer in which a deflection of π/2 radians in a radial electrostatic field analyser is followed by a magnetic deflection of π/3 radians. The electrostatic analyser uses a symmetrical object-image arrangement and the magnetic analyser is used asymmetrically. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 Orange Book, p. 201 | 
| IUPAC Gold Book | 
| Index of Gold Book Terms | 