Mattauch-Herzog geometry: Difference between revisions
|  rm section heads , Replaced: == Orange Book entry == ‚Üí <!-- Orange Book -->, using AWB | No edit summary | ||
| Line 1: | Line 1: | ||
| {{Def2| | {{Def2| | ||
| An arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/(4 √(2)) radians in a radial [[electric field]] is followed by a [[magnetic deflection]] ofπ/2 radians. | An arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/(4 √(2)) radians in a radial [[electric field]] is followed by a [[magnetic deflection]] ofπ/2 radians. | ||
| }} | |||
| {{rev5 | |||
| | | |||
| An arrangement for a double-focusing mass spectrograph in which a deflection of ?/(4 ?(2)) radians in a radial electrostatic energy analyzer is followed by a magnetic deflection of ?/2 radians.  | |||
| Related term:  [[Nier-Johnson geometry]]. | |||
| | | |||
| #[[Gold Book]] | |||
| #[[Orange Book]] | |||
| }} | }} | ||
| Line 8: | Line 18: | ||
| }} | }} | ||
| {{gold| | |||
| http://goldbook.iupac.org/M03761.html | |||
| An arrangement for a double-focusing mass spectrograph in which a deflection of   radians in a radial electrostatic field is followed by a magnetic deflection of  radians. | |||
| Source: | |||
| PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | |||
| }} | |||
| == See also == | == See also == | ||
| *[[Double-focusing Mass Spectrometer]] | *[[Double-focusing Mass Spectrometer]] | ||
Revision as of 23:27, 5 June 2010
Obsolete Template
This template is no longer used.
Orange Book
| ORANGE BOOK DEFINITION IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) | 
| Mattauch-Herzog geometry | 
|---|
| An arrangement for a double-focusing mass spectrograph in which a deflection of π/(4 √(2)) radians in a radial electrostatic field is followed by a magnetic deflection of π/2 radians. | 
| IUPAC 1997 Orange Book Chapter 12 | 
| Index of Orange Book Terms | 
Gold Book
| GOLD BOOK DEFINITION IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). | 
| Mattauch-Herzog geometry | 
|---|
| http://goldbook.iupac.org/M03761.html An arrangement for a double-focusing mass spectrograph in which a deflection of radians in a radial electrostatic field is followed by a magnetic deflection of radians. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | 
| IUPAC Gold Book | 
| Index of Gold Book Terms | 