Linked scan at constant B(1-(E/E0))1/2/E: Difference between revisions

From Mass Spec Terms
rm section heads , Replaced: == Orange Book entry == ‚Üí <!-- Orange Book -->, using AWB
change using AWB
Line 9: Line 9:


<!-- Orange Book -->
<!-- Orange Book -->
{{Orange|
{{orange|
This can be performed with a sector instrument incorporating at least one electric sector plus one magnetic sector. The magnetic sector field strength, B, and the electric sector field strength, E, are scanned simultaneously, while holding the accelerating voltage , V, constant, so as to maintain the ratio B [1- (E /E 0)]1/2 /E constant. This constant value is equal to B3/E0, where E0 and B3 are respectively the electric and magnetic sector fields required to transmit M3+ ions in the main ion beam; m3 represents the mass (m1-m2) of the selected neutral fragment M3 whose precursor spectrum is required. The fragmentation reactions thus observed occur in a field-free region traversed before the two sectors scanned in this way. The term 'B [1- (E /E 0)]1/2/E linked scan????????????????????????? is not recommended.
This can be performed with a sector instrument incorporating at least one electric sector plus one magnetic sector. The magnetic sector field strength, B, and the electric sector field strength, E, are scanned simultaneously, while holding the accelerating voltage , V, constant, so as to maintain the ratio B [1- (E /E 0)]1/2 /E constant. This constant value is equal to B3/E0, where E0 and B3 are respectively the electric and magnetic sector fields required to transmit M3+ ions in the main ion beam; m3 represents the mass (m1-m2) of the selected neutral fragment M3 whose precursor spectrum is required. The fragmentation reactions thus observed occur in a field-free region traversed before the two sectors scanned in this way. The term 'B [1- (E /E 0)]1/2/E linked scan????????????????????????? is not recommended.
}}
}}

Revision as of 23:53, 25 July 2009

Obsolete Template

Orange Book

ORANGE BOOK DEFINITION

IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023)

Linked scan at constant B(1-(E/E0))1/2/E

This can be performed with a sector instrument incorporating at least one electric sector plus one magnetic sector. The magnetic sector field strength, B, and the electric sector field strength, E, are scanned simultaneously, while holding the accelerating voltage , V, constant, so as to maintain the ratio B [1- (E /E 0)]1/2 /E constant. This constant value is equal to B3/E0, where E0 and B3 are respectively the electric and magnetic sector fields required to transmit M3+ ions in the main ion beam; m3 represents the mass (m1-m2) of the selected neutral fragment M3 whose precursor spectrum is required. The fragmentation reactions thus observed occur in a field-free region traversed before the two sectors scanned in this way. The term 'B [1- (E /E 0)]1/2/E linked scan????????????????????????? is not recommended.

IUPAC 1997 Orange Book Chapter 12
Index of Orange Book Terms