Resolution: peak width definition: Difference between revisions
From Mass Spec Terms
→[[Orange Book]] Entry: clean up using AWB |
→Orange Book Entry: change case in heading, Replaced: Book Entry == ‚Äö√ú√≠ Book entry ==, using AWB |
||
Line 1: | Line 1: | ||
== Orange Book | == Orange Book entry == | ||
For a single peak made up of singly charged ions at mass m in a [[Mass Spectrum|mass spectrum]], the resolution may be expressed as m / ??????????????????????m, where ??????????????????????m is the width of the peak at a height which is a specified fraction of the maximum peak height. It is recommended that one of three values 50%, 5% or 0.5% should always be used. (Note that for an isolated symmetrical peak recorded with a system which is linear in the range between 5% and 10% levels of the peak, the 5% peak width definition is equivalent to the 10% valley definition. A common standard is the definition of resolution based upon ??????????????????????m being Full Width of the peak at Half its Maximum (FWHM) height. | For a single peak made up of singly charged ions at mass m in a [[Mass Spectrum|mass spectrum]], the resolution may be expressed as m / ??????????????????????m, where ??????????????????????m is the width of the peak at a height which is a specified fraction of the maximum peak height. It is recommended that one of three values 50%, 5% or 0.5% should always be used. (Note that for an isolated symmetrical peak recorded with a system which is linear in the range between 5% and 10% levels of the peak, the 5% peak width definition is equivalent to the 10% valley definition. A common standard is the definition of resolution based upon ??????????????????????m being Full Width of the peak at Half its Maximum (FWHM) height. | ||
[[Category:Resolution]] | [[Category:Resolution]] |
Revision as of 23:14, 13 July 2009
Orange Book entry
For a single peak made up of singly charged ions at mass m in a mass spectrum, the resolution may be expressed as m / ??????????????????????m, where ??????????????????????m is the width of the peak at a height which is a specified fraction of the maximum peak height. It is recommended that one of three values 50%, 5% or 0.5% should always be used. (Note that for an isolated symmetrical peak recorded with a system which is linear in the range between 5% and 10% levels of the peak, the 5% peak width definition is equivalent to the 10% valley definition. A common standard is the definition of resolution based upon ??????????????????????m being Full Width of the peak at Half its Maximum (FWHM) height.