Fixed precursor ion scan: Difference between revisions
| No edit summary | No edit summary | ||
| (7 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
| {{ | {{Final | ||
| |acronym= | |||
| |def=Scan that determines, in a single experiment, the ''[[m/z]]'' values of [[product ion]]s that are produced by the reaction of a selected [[precursor ion]] with a user-specified ''m/z'' value. | |||
| |rel= | |||
| |ref={{obgb}} | |||
| }} | }} | ||
| <!-- Orange Book --> | |||
| {{orange| | |||
| A scan that determines, in a single experiment, all the [[daughter ion]] [[mass/charge ratio]]s that are produced by the reaction of a selected [[parent ion]] [[mass-to-charge ratio]]. | A scan that determines, in a single experiment, all the [[daughter ion]] [[mass/charge ratio]]s that are produced by the reaction of a selected [[parent ion]] [[mass-to-charge ratio]]. | ||
| }} | |||
| <!-- Gold Book --> | |||
| {{gold| | |||
| http://goldbook.iupac.org/F02405.html | |||
| A scan which determines, in a single experiment, all the daughter ion mass-to-charge ratios that are produced by the reaction of a selected parent ion mass-to-charge ratio. | |||
| Source: PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1551 | |||
| }} | |||
| [[Category:Sequential m/z Separation]] | [[Category:Sequential m/z Separation]] | ||
| [[Category:Orange Book term]] | |||
| {{DEFAULTSORT:Fixed Precursor Ion Scan}} | |||
Latest revision as of 15:47, 17 June 2013
| IUPAC RECOMMENDATIONS 2013 | 
| Fixed precursor ion scan | 
|---|
| Scan that determines, in a single experiment, the m/z values of product ions that are produced by the reaction of a selected precursor ion with a user-specified m/z value. | 
| Related Term(s): | 
| Reference(s): IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979. Compiled by J. Inczdy, T. Lengyel, A. M. Ure. Blackwell Scientific Publications, Oxford (1997). On-line corrected version: http://www.iupac.org /publications/analytical compendium (2000). IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). XML on-line corrected version: http://goldbook.iupac.org (2006-) created by M. Nic, J. Jirat, B. Kosata; updates compiled by A. Jenkins. | 
| From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013. | 
Orange Book
| ORANGE BOOK DEFINITION IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) | 
| Fixed precursor ion scan | 
|---|
| A scan that determines, in a single experiment, all the daughter ion mass/charge ratios that are produced by the reaction of a selected parent ion mass-to-charge ratio. | 
| IUPAC 1997 Orange Book Chapter 12 | 
| Index of Orange Book Terms | 
Gold Book
| GOLD BOOK DEFINITION IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). | 
| Fixed precursor ion scan | 
|---|
| http://goldbook.iupac.org/F02405.html A scan which determines, in a single experiment, all the daughter ion mass-to-charge ratios that are produced by the reaction of a selected parent ion mass-to-charge ratio. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1551 | 
| IUPAC Gold Book | 
| Index of Gold Book Terms | 
