Mattauch-Herzog geometry: Difference between revisions
|  →Orange Book Entry: change case in heading, Replaced: Book Entry == ‚Äö√ú√≠ Book entry ==, using AWB | No edit summary | ||
| (7 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
| {{ | {{Final | ||
| |acronym= | |||
| |def=Arrangement for a [[double-focusing]] [[mass spectrograph]] in which a deflection of π/(4 √(2)) [[wikipedia:Radian|rad]] in a radial electrostatic energy analyzer is followed by a magnetic deflection of π/2 rad. | |||
| |rel=[[Nier-Johnson geometry]] | |||
| |ref={{obgb}} | |||
| }} | }} | ||
| <!-- Orange Book --> | |||
| {{orange| | {{orange| | ||
| An arrangement for a [[double-focusing mass spectrograph]] in which a deflection of π/(4 √(2)) radians in a radial electrostatic field is followed by a [[magnetic deflection]] of π/2 radians. | An arrangement for a [[double-focusing mass spectrograph]] in which a deflection of π/(4 √(2)) radians in a radial electrostatic field is followed by a [[magnetic deflection]] of π/2 radians. | ||
| }} | }} | ||
| {{gold| | |||
| http://goldbook.iupac.org/M03761.html | |||
| An arrangement for a double-focusing mass spectrograph in which a deflection of   radians in a radial electrostatic field is followed by a magnetic deflection of  radians. | |||
| Source: | |||
| PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | |||
| }} | |||
| [[Category:M/z Separation]] | [[Category:M/z Separation]] | ||
| [[Category:Mass spectrometer type]] | |||
Latest revision as of 11:38, 6 August 2025
| IUPAC RECOMMENDATIONS 2013 | 
| Mattauch-Herzog geometry | 
|---|
| Arrangement for a double-focusing mass spectrograph in which a deflection of π/(4 √(2)) rad in a radial electrostatic energy analyzer is followed by a magnetic deflection of π/2 rad. | 
| Related Term(s): Nier-Johnson geometry | 
| Reference(s): IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979. Compiled by J. Inczdy, T. Lengyel, A. M. Ure. Blackwell Scientific Publications, Oxford (1997). On-line corrected version: http://www.iupac.org /publications/analytical compendium (2000). IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). XML on-line corrected version: http://goldbook.iupac.org (2006-) created by M. Nic, J. Jirat, B. Kosata; updates compiled by A. Jenkins. | 
| From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013. | 
Orange Book
| ORANGE BOOK DEFINITION IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) | 
| Mattauch-Herzog geometry | 
|---|
| An arrangement for a double-focusing mass spectrograph in which a deflection of π/(4 √(2)) radians in a radial electrostatic field is followed by a magnetic deflection of π/2 radians. | 
| IUPAC 1997 Orange Book Chapter 12 | 
| Index of Orange Book Terms | 
Gold Book
| GOLD BOOK DEFINITION IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). | 
| Mattauch-Herzog geometry | 
|---|
| http://goldbook.iupac.org/M03761.html An arrangement for a double-focusing mass spectrograph in which a deflection of radians in a radial electrostatic field is followed by a magnetic deflection of radians. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | 
| IUPAC Gold Book | 
| Index of Gold Book Terms | 
