| {{ | {{def | ||
| |acronym= (written MS<sup>E</sup>) | |acronym= (written MS<sup>E</sup>) | ||
| |def=Method for [[tandem mass spectrometry]] data acquisition using alternating [[low-energy collision-induced dissociation]] and [[high-energy collision-induced dissociation]] where the former is used to obtain [[precursor ion]] [[accurate mass]] and intensity data for quantification and the latter is used to obtain [[product ion]] accurate mass. | |def=Method for [[tandem mass spectrometry]] data acquisition using alternating [[low-energy collision-induced dissociation]] and [[high-energy collision-induced dissociation]] where the former is used to obtain [[precursor ion]] [[accurate mass]] and intensity data for quantification and the latter is used to obtain [[product ion]] accurate mass. | ||
| Line 5: | Line 5: | ||
| |ref=Silva JC, Denny R, Dorschel C, Gorenstein MV, Li GZ, Richardson K, Wall D, Geromanos SJ. Simultaneous Qualitative and Quantitative Analysis of the E. coli Proteome: A Sweet Tale Mol Cell Proteomics. 2006 Apr;5(4):589-607 http://dx.doi.org/10.1074/mcp.M500321-MCP200 | |ref=Silva JC, Denny R, Dorschel C, Gorenstein MV, Li GZ, Richardson K, Wall D, Geromanos SJ. Simultaneous Qualitative and Quantitative Analysis of the E. coli Proteome: A Sweet Tale Mol Cell Proteomics. 2006 Apr;5(4):589-607 http://dx.doi.org/10.1074/mcp.M500321-MCP200 | ||
| }} | }} | ||
| {{ext}}10.1016/S1044-0305(02)00420-8 | |||
| [[Category:acronym]] | [[Category:acronym]] | ||
| {{DEFAULTSORT:MSE}} | {{DEFAULTSORT:MSE}} | ||
Latest revision as of 22:30, 18 October 2016
| DRAFT DEFINITION | 
| MSE (written MSE) | 
|---|
| Method for tandem mass spectrometry data acquisition using alternating low-energy collision-induced dissociation and high-energy collision-induced dissociation where the former is used to obtain precursor ion accurate mass and intensity data for quantification and the latter is used to obtain product ion accurate mass. | 
| Related Term(s): | 
| Reference(s): Silva JC, Denny R, Dorschel C, Gorenstein MV, Li GZ, Richardson K, Wall D, Geromanos SJ. Simultaneous Qualitative and Quantitative Analysis of the E. coli Proteome: A Sweet Tale Mol Cell Proteomics. 2006 Apr;5(4):589-607 http://dx.doi.org/10.1074/mcp.M500321-MCP200 | 
| This is an unofficial draft definition presented for information and comment. | 